Contacts Board Members News Homes/Land FAQs Jobs Forms Emer Resources Procurement Resources Section 8 Landlord Info Public Housing Services HRHA Intranet
Home


 

 

Landlord Information

HRHA needs more landlords for our Housing Voucher Choice (Section 8) program. If you’d like to learn what’s involved, please call 757-727-1521 x301.

direct deposit
[New!]
We now offer free Direct Deposit for our landlords.  Please download, fill out, and mail the form with a voided check (checking account) or deposit slip (savings account) attached to enroll.

landlord news
[New!]HUD Charges Mississippi Housing Authority, Property Managers, and Apartment Complex with Violating Fair Housing Act

list your property
Use the GoSection8 database to find listings or to list your Section 8 property.
 

Landlords are now able to submit their listing of an available unit by using the free service offered by www.gosection8.com. This service allows tenants, landlords, and the housing authority to easily access information on available units. The service also allows landlords to upload pictures of the property.

By partnering with www.gosection8.com, HRHA will be able to still offer the value added service of free print and online listings but with less overhead, allowing more time to devote to our clients and landlords.

Below are answers to some our frequently asked landlord questions, steps to participate, and copy of our W-9 form which landlords submit to change their address or payee status.
 

Frequent Questions

Steps to participate

Forms

Landlord Class

Inspection Checklist

HUD's Landlord page
 

frequent questions

Does my unit have to be pre-approved?  The unit does not have to be inspected prior to screening a tenant.  The unit must be inspected and passing prior to the tenant taking possession or subsidy beginning.

Who pays the security deposit?  The tenant is responsible for the entire security deposit.

How long does it take for my unit to be approved?  Once the move in packet is completed and received by the Housing Authority, an inspector will call to schedule an inspection between one and 10 business days.

If my rent is more than the HRHA can approve, can the tenant pay the difference?
No.  Rents may be above the payment standards but must be approved by the HRHA inspector.  A tenant must not pay any additional monies out of pocket to the landlord without HRHA approval.

If the tenant violates the lease agreement, is it possible to evict a Section 8 tenant?  If a tenant violates a lease agreement, the landlord must treat that tenant as they would any non-subsidized tenant. The only difference in the eviction process is that the landlord must send copies of all legal notices to HRHA.

Who pays if there are any damages?  The tenant is responsible for all damages.

Note: additional answers to frequently asked questions are available on our FAQ page.

return to the top


steps to participate

  1. Attend a landlord briefing to get information about the S8 program.

  2. Screen the perspective tenant just as you would a non-assisted tenant, keeping in mind the Fair Housing laws.

  3. Check the clients voucher for 2 things; the expiration date and the number of bedrooms the family qualifies for.

  4. Fill out the RFTA (request for tenancy approval) packet carefully and completely.  Return to the technician.

  5. The housing technician will process the request determining if the rent is reasonable (fair market) and affordable for the client.

  6. The inspection request is forwarded to the inspection department and you will be contacted to schedule an inspection.

  7. Make sure all of the utilities are on and all appliances in place prior to inspection.

  8. Do not allow the client to move into the unit prior to it passing inspection.  HRHA cannot pay on a unit that has not passed inspection.

  9. The inspector will note any deficiencies (and give them to you in writing), make the final determination on a reasonable rent, and return for a re-inspection if necessary.

  10. When the unit passes inspection, contact the technician before allowing the tenant to move in.

  11. Sign the lease, and collect the security deposit from your new tenant.  Sign the contract with the Housing Authority.

  12. Accept our thanks for your participation in HRHA's S8 program!

return to the top


forms

Need the Adobe PDF reader?  They will also offer to include a photo album tool and a download utility.  It is not necessary or recommended that you download these additional components.
  getacro.gif (2143 bytes)

return to the top


landlord class

[New!]A class for new landlords is held once per month at the office located at 811 West Pembroke Ave.  Class times are from 2:30 - 3:30 pm.  Please contact our Inspection Assistant at 757-727-1521 extension 301 to register.

return to the top


HRHA Self Inspection Checklist

The HRHA Housing Quality Standards (HQS) are composed of the stricter of the HUD HQS and The International Property Maintenance Code, as adopted by the City of Hampton. In most cases the property maintenance code prevails.

Listed below is a general checklist of the most common reasons a unit may fail inspection. This listing is not a complete listing of the above codes. Please contact Jerry Hoffman, Chief Inspector at 757-727-1521 extension 312
[New!] if you have questions.

Exterior Site and Property Requirements
 

bullet

All exterior property - Shall be maintained in clean, safe & sanitary condition.

bullet

Sidewalks & driveways - Shall be kept in a proper state of repair.

bullet

Accessory structures - (sheds, garages, fences) - Shall be structurally sound and in good repair. No deteriorated paint (see lead-based paint)

bullet

Inoperable vehicles – without valid inspection or plates shall be removed.

bullet

Grading - Premises shall not allow the accumulation of surface or stagnant water

bullet

Weeds – Premises shall be free of noxious weeds & plant growth over 10 inches.
 

Exterior Structure
 

bullet

Premises Identification – Address numbers shall be visible from the street.

bullet

Foundation walls – Shall be structurally sound, plumb, free from cracks, holes, prevent the entry of rodents & pests. No standing water in basement or crawl spaces.

bullet

Roofs – Shall be free from defects that admit rain; no missing or loose shingles.

bullet

Gutters & downspouts - shall be in good repair & discharge water away from unit.

bullet

Exterior walls, cornices, soffit & trim – Shall be structurally sound, free from holes, breaks, loose or rotting material, weatherproof and properly surface coated by painting or other protective coating. All deteriorated paint must be repaired. (see lead-based paint)

bullet

Stairways, decks, porches & balconies – Shall be in good repair, properly anchored, capable of supporting all imposed loads, handrails are required for four (4) or more steps (landing is counted as a step), Guardrails are required for any step, deck, porch or balcony that is thirty (30”) or more above grade. Installations must be in accordance with the International Residential Code.

bullet

Windows – Shall be in good repair, weather tight, have locks, easily openable and capable of being held in position by window hardware; must have properly fitted screen. No deteriorated paint (see lead-based paint).

bullet

Doors - Exterior doors, jamb and hardware shall be in good repair, weather tight, have deadbolt locks & shall be easily openable from the egress side without the use of a key or special knowledge (manual knob required on the interior).

bullet

Lead-based paint (exterior) – All deteriorated paint surfaces must be repaired. This includes windows, window sills, exterior walls, porches, floors, railings, doors decks, stairs, play areas, garages, fences or other areas on the premises. If the unit is built prior to 1978 and a child under six (6) years of age will occupy the unit, the following will apply: Deteriorated paint surfaces more than 20 square feet on exterior must be stabilized (corrected) in accordance with CFR 24, Part 35 (all safe work practice requirements). This includes clearance testing from a certified person, licensed in Virginia. If the painted surface is less than 20 square feet, only stabilization is required. Stabilization means the removal of deteriorated paint, repair of the substrate, and application of two (2) new protective coatings or paint. A lead-based paint Owners Certification is required following stabilization activities.

Interior Structure
 

bullet

General – The interior structure shall be in good repair. All structural members shall be sound and capable of supporting all imposed loads, all areas shall be clean, safe and sanitary. All rooms shall have a minimum ceiling height of seven feet (7’) (exceptions for bedrooms with sloped ceilings & basement rooms with beams), All habitable rooms shall have two separate and remote electrical receptacle outlets.

bullet

Interior surfaces – All surfaces shall be clean, safe & sanitary including floors, windows, doors, walls, kitchen and bathroom fixtures & appliances, No deteriorated paint or plaster. (see lead-based paint below)

bullet

Handrails & guardrails – Required as stated in “stairways” above.

bullet

Infestation – All structures shall be kept free from rodent and insect infestation.

bullet

Bathrooms - Shall have a window or exhaust fan for ventilation; shall contain at least one electrical receptacle (new installation must be GFCI), floors & walls shall be a nonabsorbent surface impervious to water.

bullet

Bedrooms - Shall contain at least seventy (70) square feet of floor area, more than one occupant requires 50 square feet for each person, (2 persons = 100 sq. ft.), have a minimum width of seven (7) feet, have an openable window, have two separate & remote electrical receptacle outlets.

bullet

Kitchens – Must be provided with stoves, ovens refrigerators, freezers (supplied by tenant or landlord) that are properly installed & maintained, cabinets countertops & drawers in sufficient quantity & condition that occupants can store, prepare & serve foods in a sanitary manner.

bullet

Laundry or Utility rooms - Shall contain at least one grounded-type receptacle, clothes dryers shall be vented to the outside.

bullet

Lighting fixtures – Every public hall, interior stairway, kitchen, bathroom, laundry room, boiler room, and furnace room shall contain at least one electric lighting fixture.

bullet

Electrical – Electrical service to the unit shall be adequately sized to avoid overloading, All electrical fixtures, wiring, receptacles, panel boxes, fuses, breakers, splices, grounds, appliances and equipment shall be properly installed and maintained in a safe and approved manner.

bullet

Smoke detectors – Shall be installed as follows: on the ceiling or wall outside of each separate sleeping area, in each bedroom, in each story within a dwelling unit including basements, shall be equipped with a battery backup.

bullet

Plumbing – All plumbing fixtures shall be properly installed, free from leaks, defects, deterioration, must not have low pressure, inadequate venting, cross connections, all sinks and toilets must have shut off valves, backflow prevention assemblies where applicable.

bullet

Water Heaters – Shall be capable of providing an adequate amount of water at every required plumbing fixture at a temperature not less than 110 degrees, Shall have a temperature & pressure relief valve and discharge pipe extending to within six (6”) inches of the floor, gas water heaters shall not be located in any room normally kept closed unless adequate combustion air is provided, exposed gas water heaters in living areas shall have safety dividers or shields.

bullet

Heating Facilities – Heating systems shall be properly installed, maintained & capable of maintaining a room temperature of 65 degrees from October 15th through May 1st in all habitable rooms & bathrooms (measured 3 feet above the floor), No portable unvented fuel burning space heaters

bullet

Chimney & vents – Must be capable of creating sufficient draft to properly vent the appliances served, shall be free of leaks, deterioration, loose bricks, creosote deposits, have adequate clearance from combustible materials.

bullet

Lead-based paint (Interior) – All deteriorated paint surfaces must be repaired. This includes building components within the unit : walls, floors, ceilings cabinets, baseboards, doors, door frames and any part of the window system. Deteriorated paint includes any surface that is peeling, chipping, chalking, damaged or otherwise separated from the substrate. If the unit was built prior to 1978 and a child under six (6) years of age will occupy the unit, the following will apply: All deteriorated paint surfaces more than 2 square feet in any one interior room or space, or more than 10% of the total surface area of an interior type component (window sill, baseboard or trim) must be stabilized (corrected) in accordance with CFR 24, Part 35 (all safe work practice requirements). This includes clearance testing from a certified person, licensed in Virginia. If the deteriorated paint surface is less than 2 square feet or less than 10%, only stabilization is required. Stabilization means the removal of deteriorated paint, repair of the substrate, and application of two (2) new protective coatings or paint. A lead-based paint Owners Certification is required following stabilization activities.
 

Remember…..